Choose the brand aligned with your industry so we can best serve your needs.
For researchers, scientists, and technical professionals: Your one-stop shop for the complete range of laboratory, production, and safety products and services.
Products and accessories for analysis of water sample quality; includes BOD and COD testing equipment, coliform detection tests, cyanide distillation apparatuses, dissolved oxygen meters, glassware, Imhoff cones and water quality testing kits.
Reagent set for the determination of Total Hardness by the ManVer 2 Buret Titration Method (Hach method 8226). EPA Accepted method. Range: 0-2,500 mg/L as CaCO3. Contains: Buffer Solution (Hardness 1), ManVer 2 Hardness Indicator Powder Pillows and 0.0200 N EDTA (TitraVer) Titrant for up to approximately 100 tests.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
For determination of low range Molybdate Molybdenum by the Ternary Complex method. Hach Method 8169. Range: 0.02 - 3.00 mg/L Mo Sample Size: 20 mL Reagent Set includes: Molybdenum 1 Reagent (LR) Molybdate Powder Pillows and Molybdenum 2 Reagent Solution for approximately 100 tests.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
BART biodetectors are excellent diagnostic tools to help identify the presence and activity of various bacteria. Heterotrophic Aerobic Bacteria (HAB) are one of the most important agents in biofouling, causing corrosion, clogging, fouling of the water, and increased hygiene risks.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
For determination of Aluminum by the Eriochrome Cyanine R (ECR) Method. Hach Method 8326. Sample Size: 50 mL Range: 0.002 - 0.220 mg/L. Reagent set contains ECR Reagent Powder Pillows, Hexamethylenetetramine Buffer Reagent Powder Pillows and ECR Masking Reagent Solution for approximately 100 tests.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Hach glass microfiber filters are designed to exceed ASTM and Standard Methods protocols including 2540 C, 2540 D, and 2540 E. Our filters have a smooth surface and are binder-free with unique high temperature resistance. The 1.0 µm retention offers fast speed as well as a very high loading capacity. Hach glass filters are designed to maintain a stable weight before and after treatment in excess of 550 °C. This is an important attribute for customers performing Fixed and Volatile Solids analysis of water and wastewater.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Hach glass microfiber filters are designed to exceed ASTM and Standard Methods protocols including 2540 C, 2540 D, and 2540 E. Our filters have a smooth surface and are binder-free with unique high temperature resistance. The 1.0 µm retention offers fast speed as well as a very high loading capacity. Hach glass filters are designed to maintain a stable weight before and after treatment in excess of 550 °C. This is an important attribute for customers performing Fixed and Volatile Solids analysis of water and wastewater.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
For determination of reactive Phosphorus (Phosphate) by the ascorbic acid method, using PhosVer 3 Phosphate Reagent AccuVac Ampules. USEPA accepted for reporting for wastewater analysis using Hach Method 8048. Range: 0.02 - 2.50 mg/L as PO4 Pack of 25 ampules.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Sludge Judge accessories help maintain a long, trouble-free service life. Cleaning brush not recommended for cleaning oil and grease. Use Grease Trap Cleaning Rod in conjunction with Cleaning Strips and a mild detergent to effectively remove oil & grease from plastic tubing.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
For high range phosphate (phosphorus) determination by the amino acid method (Hach method 8178). Range: Up to 30 mg/L PO₄ 100 mL Marked Dropping Bottle
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More